Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 124
Filtrar
1.
JACC Clin Electrophysiol ; 10(4): 709-715, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38310489

RESUMO

BACKGROUND: High-voltage pulses can cause hemolysis. OBJECTIVES: The authors evaluated the occurrence of hemoglobinuria after pulsed-field ablation (PFA) and its impact on renal function in patients with atrial fibrillation (AF). METHODS: A consecutive series of patients with AF undergoing PFA were included in this analysis. The initial patients who did not receive postablation hydration immediately after the procedure were classified as group 1 (n = 28), and the rest of the study patients who received planned fluid infusion (0.9% sodium chloride ≥2 L) after the procedure were categorized as group 2 (n = 75). RESULTS: Of the 28 patients in group 1, 21 (75%) experienced hemoglobinuria during the 24 hours after catheter ablation. The mean postablation serum creatinine (S-Cr) was significantly higher than the baseline value in those 21 patients (1.46 ± 0.28 mg/dL vs 0.86 ± 0.24 mg/dL, P < 0.001). Of those 21 patients, 4 (19%) had S-Cr. >2.5 mg/dL (mean: 2.95 ± 0.21 mg/dL). The mean number of PF applications was significantly higher in those 4 patients than in the other 17 patients experiencing hemoglobinuria (94.63 ± 3.20 vs 46.75 ± 9.10, P < 0.001). In group 2 patients, no significant changes in S-Cr were noted. The group 2 patients received significantly higher amounts of fluid infusion after catheter ablation than did those in group 1 (2,082.50 ± 258.08 mL vs 494.01 ± 71.65 mL, P < 0.001). In multivariable analysis, both hydration (R2 = 0.63, P < 0.01) and number of PFA applications (R2 = 0.33, P < 0.01) were independent predictors of postprocedure acute kidney injury. CONCLUSIONS: On the basis of our findings, both the number of PFA applications and postablation hydration were independent predictors of renal insult that could be prevented using planned fluid infusion immediately after the procedure.


Assuntos
Injúria Renal Aguda , Fibrilação Atrial , Ablação por Cateter , Hemoglobinúria , Humanos , Fibrilação Atrial/cirurgia , Masculino , Feminino , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Pessoa de Meia-Idade , Injúria Renal Aguda/prevenção & controle , Injúria Renal Aguda/etiologia , Idoso , Hemoglobinúria/etiologia , Hemoglobinúria/prevenção & controle , Creatinina/sangue , Estudos Retrospectivos , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/etiologia , Hidratação/métodos
2.
Heart Rhythm ; 21(4): 410-418, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38246594

RESUMO

BACKGROUND: Outcome comparisons among subcutaneous implantable cardioverter-defibrillator (S-ICD) recipients with nonischemic cardiomyopathies are scarce. OBJECTIVE: The aim of this study was to evaluate differences in device-related outcomes among S-ICD recipients with different structural substrates. METHODS: Patients enrolled in the i-SUSI (International SUbcutaneouS Implantable cardioverter defibrillator registry) project were grouped according to the underlying substrate (ischemic vs nonischemic) and subgrouped into dilated cardiomyopathy, hypertrophic cardiomyopathy, Brugada syndrome (BrS), arrhythmogenic right ventricular cardiomyopathy (ARVC). The main outcome of our study was to compare the rates of appropriate and inappropriate shocks and device-related complications. RESULTS: Among 1698 patients, the most common underlying substrate was ischemic (31.7%), followed by dilated cardiomyopathy (20.5%), BrS (10.8%), hypertrophic cardiomyopathy (8.5%), and ARVC (4.4%). S-ICD for primary prevention was more common in the nonischemic cohort (70.9% vs 65.4%; P = .037). Over a median (interquartile range) follow-up of 26.5 (12.6-42.8) months, no differences were observed in appropriate shocks between ischemic and nonischemic patients (4.8%/y vs 3.9%/y; log-rank, P = .282). ARVC (9.0%/y; hazard ratio [HR] 2.492; P = .001) and BrS (1.8%/y; HR 0.396; P = .008) constituted the groups with the highest and lowest rates of appropriate shocks, respectively. Device-related complications did not differ between groups (ischemic: 6.4%/y vs nonischemic: 6.1%/y; log-rank, P = .666), nor among underlying substrates (log-rank, P = .089). Nonischemic patients experienced higher rates of inappropriate shocks than did ischemic S-ICD recipients (4.4%/y vs 3.0%/y; log-rank, P = .043), with patients with ARVC (9.9%/y; P = .001) having the highest risk, even after controlling for confounders (adjusted HR 2.243; confidence interval 1.338-4.267; P = .002). CONCLUSION: Most S-ICD recipients were primary prevention nonischemic cardiomyopathy patients. Among those, patients with ARVC tend to receive the most frequent appropriate and inappropriate shocks and patients with BrS the least frequent appropriate shocks.


Assuntos
Displasia Arritmogênica Ventricular Direita , Cardiomiopatias , Cardiomiopatia Dilatada , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Morte Súbita Cardíaca/epidemiologia , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Cardioversão Elétrica/efeitos adversos , Displasia Arritmogênica Ventricular Direita/complicações , Cardiomiopatia Dilatada/complicações , Cardiomiopatia Dilatada/terapia , Sistema de Registros , Resultado do Tratamento
4.
JACC Clin Electrophysiol ; 9(8 Pt 3): 1824-1835, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37648342

RESUMO

The overall survival in patients undergoing lung transplantation is poor. Although postsurgical atrial arrhythmias seem to play a major role in the morbidity and mortality of this population, data regarding the clinical and interventional management of this complication are still controversial. Through a review of the literature in the field, we observed that not only the surgical technique is clearly arrhythmogenic, but the new administration of peri-procedure beta-blockers and amiodarone for arrhythmia prevention and treatment, respectively, seems harmful in these postsurgical patients. However, low-dose beta-blockers administered after surgery seem feasible in arrhythmia prevention in specific patient subgroups, and, aside from amiodarone, alternative antiarrhythmic agents can be safely and effectively used to treat symptomatic patients on top of adequate rate control. Finally, as to complex atrial arrhythmias occurring late after lung transplant surgery, radiofrequency catheter ablation seems a feasible treatment option. In light of this evidence and considering the absence of clear recommendations in the field, we suggest a practical approach that may help the clinician in the management of this postsurgical complication. However, as most of these considerations are drawn from small-sized and retrospective studies, more evidence is needed in the future to clarify which medical and interventional strategies may best treat these postsurgical arrhythmias and thus potentially improve the outcome of these frail patients.


Assuntos
Amiodarona , Fibrilação Atrial , Transplante de Pulmão , Humanos , Fibrilação Atrial/cirurgia , Estudos Retrospectivos , Transplante de Pulmão/efeitos adversos , Antiarrítmicos/uso terapêutico
5.
J Pers Med ; 13(5)2023 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-37240913

RESUMO

The antibody-related immune response is mediated by immunoglobulins (Igs), soluble circulating glycoproteins produced by activated B cells that, upon the recognition of specific epitopes on pathogen surfaces, activate, proliferate, and differentiate into antibody-secreting plasma cells. Although the antibodies are effectors of the humoral immune adaptive response, their overproduction in response to a dysregulated proliferation of clonal plasma cell production in tumoral conditions (i.e., multiple myeloma), enriches the serum and urinary matrices, assuming the crucial role of biomarkers. Multiple myeloma (MM) is a plasma cell dyscrasia characterized by the expansion and accumulation of clonally activated plasma cells in bone marrow, determining the release of high amounts of monoclonal component (MC) that can be detected as intact immunoglobulin (Ig), immunoglobulin fragments, or free light chains (FLCs). The importance of detecting biomarkers for the diagnosis, monitoring, and prognosis of diseases is highlighted by the international guidelines that recommend specific assays for the analysis of intact Igs and FLC. Moreover, a developed assay called Hevylite® allows for the quantification of immunoglobulins that are both involved (iHLC) and not involved (uHLC) in the tumor process; this is a fundamental aspect of following up the patient's workup and evaluating the progression of disease, together with the treatments response. We here summarize the major points of the complex scenario involving monoclonal gammopathies and MM clinical management in view of advantages derived for the use of Hevylite®.

6.
JACC Case Rep ; 7: 101700, 2023 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-36776790

RESUMO

Cystic tumors of the atrioventricular node are rare primary cardiac neoplasms, frequently reported as a postmortem diagnosis during autopsy. Despite their small size, they can present with complete heart block or sudden cardiac death. Herein, we present a case of rapidly progressing high-grade atrioventricular block that improved after surgery. (Level of Difficulty: Intermediate.).

7.
Card Electrophysiol Clin ; 15(1): 75-83, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36774139

RESUMO

Prolonged use of fluoroscopy during catheter ablation (CA) of arrhythmias is associated with a significant exposure to ionizing radiation and risk of orthopedic injuries given the need for heavy protective equipment. CA of ventricular arrhythmias (VAs) arising from the left ventricular (LV) summit is challenging, requiring a vast knowledge of the intricate cardiac anatomy of this area and careful imaging delineation of the different anatomical structures, which is frequently performed using fluoroscopic guidance. Certain techniques, including pericardial mapping and ablation, use of intracoronary wires, and mapping and ablation inside the coronary venous system have been proposed, further prolonging fluoroscopy time. Fluoroless CA procedures are feasible with currently available technology and appear to have similar safety and efficacy outcomes compared with conventional techniques. To successfully perform fluoroless CA of LV summit arrhythmias, it is important to be fully acquainted with intracardiac echocardiography (ICE) imaging and electroanatomic mapping (EAM). We will describe our approach to perform fluoroless CA in LV summit VAs.


Assuntos
Arritmias Cardíacas , Ablação por Cateter , Humanos , Resultado do Tratamento , Arritmias Cardíacas/diagnóstico por imagem , Arritmias Cardíacas/cirurgia , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Coração , Ablação por Cateter/métodos
8.
Anesth Analg ; 137(3): 618-628, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-36719955

RESUMO

BACKGROUND: The recommendation for transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) in patients 65 to 80 years of age is equivocal, leaving patients with a difficult decision. We evaluated whether TAVR compared to SAVR is associated with reduced odds for loss of independent living in patients ≤65, 66 to 79, and ≥80 years of age. Further, we explored mechanisms of the association of TAVR and adverse discharge. METHODS: Adult patients undergoing TAVR or SAVR within a large academic medical system who lived independently before the procedure were included. A multivariable logistic regression model, adjusting for a priori defined confounders including patient demographics, preoperative comorbidities, and a risk score for adverse discharge after cardiac surgery, was used to assess the primary association. We tested the interaction of patient age with the association between aortic valve replacement (AVR) procedure and loss of independent living. We further assessed whether the primary association was mediated (ie, percentage of the association that can be attributed to the mediator) by the procedural duration as prespecified mediator. RESULTS: A total of 1751 patients (age median [quartiles; min-max], 76 [67, 84; 23-100]; sex, 56% female) were included. A total of 27% (222/812) of these patients undergoing SAVR and 20% (188/939) undergoing TAVR lost the ability to live independently. In our cohort, TAVR was associated with reduced odds for loss of independent living compared to SAVR (adjusted odds ratio [OR adj ] 0.19 [95% confidence interval {CI}, 0.14-0.26]; P < .001). This association was attenuated in patients ≤65 years of age (OR adj 0.63 [0.26-1.56]; P = .32) and between 66 and 79 years of age (OR adj 0.23 [0.15-0.35]; P < .001), and magnified in patients ≥80 years of age (OR adj 0.16 [0.10-0.25]; P < .001; P -for-interaction = .004). Among those >65 years of age, a shorter procedural duration mediated 50% (95% CI, 28-76; P < .001) of the beneficial association of TAVR and independent living. CONCLUSIONS: Patients >65 years of age undergoing TAVR compared to SAVR had reduced odds for loss of independent living. This association was partly mediated by shorter procedural duration. No association between AVR approach and the primary end point was found in patients ≤65 years of age.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Humanos , Feminino , Masculino , Valva Aórtica/cirurgia , Estudos Retrospectivos , Vida Independente , Estenose da Valva Aórtica/cirurgia , Resultado do Tratamento , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Implante de Prótese de Valva Cardíaca/métodos , Fatores de Risco
9.
J Cardiovasc Electrophysiol ; 34(1): 147-152, 2023 01.
Artigo em Inglês | MEDLINE | ID: mdl-36378783

RESUMO

INTRODUCTION: Atrial fibrillation (AF) and premature ventricular complexes (PVC) are common arrhythmias. We aimed to investigate AF prevalence in patients with PVC and its impact on PVC ablation outcomes. METHODS: Consecutive patients undergoing PVC ablation at a single institution between 2016 and 2019 were included and prospectively followed for 2 years. Patients with severe valvular heart disease, hyperthyroidism, malignancy, alcohol use disorder and advanced renal/hepatic diseases were excluded. Twelve-lead electrocardiograms were used to diagnose AF and assess PVC morphology. All PVCs were targeted for ablation using 4-mm irrigated-tip catheters at standardized radiofrequency power guided by 3-D mapping and intracardiac echocardiography. Patients were followed with remote monitoring, device interrogations and office visits every 6 months for 2 years. Detection of any PVCs in follow-up was considered as recurrence. RESULTS: A total of 394 patients underwent PVC ablation and 96 (24%) had concurrent AF. Patients with PVC and AF were significantly older (68.2 ± 10.8 vs. 58.3 ± 15.8 years, p < .001), had lower LV ejection fraction (43.3 ± 13.3% vs. 49.6 ± 12.4%, p < .001), higher CHA2 DS2 -VASc (2.8 ± 1.3 vs. 2.0 ± 1.3, p < .001) than those without. PVCs with ≥2 morphologies were detected in 60.4% and 13.7% patients with vs without AF (p < .001). At 2-year follow-up, PVC recurrence rate was significantly higher in patients with vs without AF (17.7% vs. 9.4%, p = .02). CONCLUSION: AF was documented in 1/4 of patients undergoing PVC ablation and was associated with lower procedural success at long-term follow-up. This was likely attributed to older age, worse LV function and higher prevalence of multiple PVC morphologies in patients with concurrent AF.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Complexos Ventriculares Prematuros , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Prevalência , Volume Sistólico , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/epidemiologia , Complexos Ventriculares Prematuros/cirurgia , Ablação por Cateter/efeitos adversos
10.
J Interv Card Electrophysiol ; 66(6): 1383-1389, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-36456653

RESUMO

INTRODUCTION: Complex atrial tachyarrhythmias (CATs) are commonly observed in patients with prior catheter ablation or cardiac surgery. These arrhythmias are challenging to map and ablate. Historically, entrainment mapping was utilized to characterize CAT. With the advent of high-definition mapping (HDM), full visualization of the CAT circuit is possible which may obviate the need for entrainment mapping. METHODS: We sought to investigate the outcomes of catheter ablation of CAT guided only by HDM. Consecutive patients who underwent CAT ablation from 2017 to 2021 were included in our study (excluding right atrial tachyarrhythmias). Patients were sorted by the type of mapping performed. Group I consisted of patients where HDM alone was utilized with no attempt of entrainment. Group II consisted of patients where both entrainment and HDM were utilized. RESULTS: A total of 67 patients were included in our study, with 40 patients in HDM group (I) and 27 patients in entrainment group (II). No statistically significant difference regarding 1-year freedom from atrial arrhythmias was found between the two groups (80% vs 77.8%, p = 0.819). Four CATs were terminated by entrainment during procedure versus none in the HDM-only group (p = 0.011). CONCLUSIONS: CAT ablation with HDM alone yielded similar 1-year freedom from atrial arrhythmias compared to ablation with HDM and entrainment. Entrainment combined with HDM was associated with higher undesired CAT interruption rate. Further validation is needed with randomized control trials.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Humanos , Fibrilação Atrial/cirurgia , Resultado do Tratamento , Taquicardia/cirurgia , Átrios do Coração/cirurgia , Ablação por Cateter/métodos
11.
JACC Clin Electrophysiol ; 8(9): 1077-1089, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-36137711

RESUMO

BACKGROUND: VISITAG SURPOINT (VS)-guided ablation of paroxysmal atrial fibrillation has demonstrated good short- and long-term success rates with low rates of complications in recent, predominantly European, studies. However, there is a lack of multicenter data from the United States. OBJECTIVES: This U.S. study evaluated the safety and effectiveness of VS ablation using a contact force-sensing catheter for the treatment of drug-refractory symptomatic paroxysmal atrial fibrillation. METHODS: The prospective, nonrandomized VS postapproval study was conducted at 32 U.S. sites. Ablation consisted of pulmonary vein isolation with recommended VS index targets (anterior, roof, or ridge: 550; posterior or inferior: 380). Additional non-pulmonary vein triggers were ablated at the investigators' discretion. Subjects were followed for 12 months, including a 3-month blanking period. The primary safety endpoint was the primary adverse event rate up to 7 days postablation. The primary effectiveness endpoint was 12-month freedom from atrial tachyarrhythmia recurrence and an additional set of failure modes based on stringent monitoring (weekly transtelephonic monitoring [TTM] [day 91 through month 5], monthly TTM [months 6 to 12], and any symptomatic cardiac episode using TTM, plus electrocardiogram [at discharge, 1 month, 3 months, 6 months, and 12 months] with 24-hour Holter monitoring [12 months]). RESULTS: Of 283 patients enrolled, 261 had the catheter inserted and underwent ablation (safety cohort); 246 met all eligibility criteria (effectiveness cohort). Mean fluoroscopy time was 2.2 minutes. Mean amount of catheter-delivered fluid was 671 mL; only 18.0% of patients utilized a Foley catheter. Primary safety and effectiveness endpoints were met. The raw primary adverse event rate was 4.3% (14 events, n = 11). At 12 months, the Kaplan-Meier estimate of freedom from primary effectiveness failure was 76.4%; estimates of 12-month freedom from documented atrial fibrillation, atrial tachycardia, or atrial flutter recurrence were 81.5% and 92.7% per stringent monitoring and standard-of-care monitoring (excluding TTM), respectively. The first-pass isolation rate was 83.1%, represented by no acute reconnection after the 30-minute waiting period. Freedom from repeat ablation at 12 months was 94.0%. CONCLUSIONS: The VS postapproval study confirms reproducibility of clinical safety and effectiveness of the standardized VS paroxysmal atrial fibrillation ablation workflow with >80% 12-month freedom from atrial tachyarrhythmia recurrence and first-pass isolation rate of 83.1%. Procedures were performed with minimal fluoroscopy. (Evaluation of VISITAG SURPOINT™ Module With External Processing Unit [EPU]; NCT03624881).


Assuntos
Fibrilação Atrial , Ablação por Cateter , Ablação por Cateter/métodos , Humanos , Estudos Prospectivos , Reprodutibilidade dos Testes , Taquicardia/cirurgia , Resultado do Tratamento
12.
JACC Clin Electrophysiol ; 8(4): 453-461, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35246406

RESUMO

OBJECTIVES: In this study, the authors investigated the ablation success of scar homogenization with combined (epicardial + endocardial) vs endocardial-only approach for ventricular tachycardia (VT) in patients with ischemic cardiomyopathy (ICM) at 5 years of follow-up. BACKGROUND: Best ablation approach to achieve long-term success rate in VT patients with ICM is not known yet. METHODS: Consecutive ICM patients undergoing VT ablation at our center were classified into group 1: endocardial + epicardial scar homogenization and group 2: endocardial scar homogenization. Patients with previous open heart surgery were excluded. Epicardial ablation was performed despite being noninducible after endocardial ablation in all group 1 patients. All patients underwent bipolar substrate mapping with standard scar settings defined as normal tissue >1.5 mV and severe scar <0.5 mV. Noninducibility of monomorphic VT was the procedural endpoint in both groups. Patients were followed up every 4 months for 5 years with implantable device interrogations. RESULTS: A total of 361 patients (group 1: n = 70 and group 2: n = 291) were included in the study. At 5 years, 81.4% (n = 57/70) patients from group 1 and 66.3% (n = 193/291) from group 2 were arrhythmia-free (P = 0.01) Of those patients, 26 of 57 (45.6%) and 172 of 193 (89.1%) from group 1 and group 2 respectively were on anti-arrhythmic drugs (AAD) (log-rank P < 0.001). After adjusting for age, sex, and obstructive sleep apnea, endo-epicardial scar homogenization was associated with a significant reduction in arrhythmia-recurrence (HR: 0.48; 95% CI: 0.27-0.86; P = 0.02). CONCLUSIONS: In this series of patients with ICM and VT, epicardial substrate was detected in all group 1 patients despite being noninducible after endocardial ablation. Moreover, combined endo-epicardial scar homogenization was associated with a significantly higher success rate at 5 years of follow-up and a substantially lower need for antiarrhythmic drugs after the procedure compared with the endocardial ablation alone.


Assuntos
Cardiomiopatias , Ablação por Cateter , Isquemia Miocárdica , Taquicardia Ventricular , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Cicatriz/etiologia , Endocárdio/cirurgia , Humanos , Isquemia Miocárdica/complicações , Isquemia Miocárdica/cirurgia , Taquicardia Ventricular/complicações , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
13.
Heart Rhythm ; 19(1): 90-99, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34536590

RESUMO

BACKGROUND: Ventricular arrhythmias (VAs) represent a critical issue with regard to sports eligibility assessment in athletes. The ideal diagnostic evaluation of competitive and leisure-time athletes with complex VAs has not been clearly defined. OBJECTIVE: The purpose of this study was to assess the clinical implications of invasive electrophysiological assessments and endomyocardial biopsy (EMB) among athletes with VAs. METHODS: We evaluated 227 consecutive athletes who presented to our institutions after being disqualified from participating in sports because of VAs. After noninvasive tests, electrophysiological study (EPS), electroanatomic mapping (EAM), and EAM- or cardiac magnetic resonance imaging-guided EMB was performed, following a prespecified protocol. Sports eligibility status was redefined at 6-month follow-up. RESULTS: From our sample, 188 athletes (82.8%) underwent EAM and EPS, and 42 (15.2%) underwent EMB. A diagnosis of heart disease could be formulated in 30% of the study population (67/227; 95% confidence interval [CI] 0.24-0.36) after noninvasive tests; in 37% (83/227; 95% CI 31%-43%) after EPS and EAM; and in 45% (102/227; 95% CI 39%-51%) after EMB. In the subset of athletes undergoing EMB, invasive diagnostic workup allowed diagnostic reclassification of half of the athletes (n = 21 [50%]). Reclassification was particularly common among subjects without definitive findings after noninvasive evaluation (n = 23; 87% reclassified). History of syncope, abnormal echocardiogram, presence of late gadolinium enhancement, and abnormal EAM were linked to sports ineligibility at 6-month follow-up. CONCLUSION: A comprehensive invasive workup provided additional diagnostic elements and could improve the sports eligibility assessment of athletes presenting with VAs. The extensive invasive evaluation presented could be especially helpful when noninvasive tests show unclear findings.


Assuntos
Displasia Arritmogênica Ventricular Direita/diagnóstico , Atletas , Técnicas Eletrofisiológicas Cardíacas/métodos , Taquicardia Ventricular/diagnóstico , Adulto , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Biópsia , Feminino , Humanos , Masculino , Estudos Retrospectivos , Taquicardia Ventricular/fisiopatologia
14.
Heart Rhythm ; 19(1): 30-38, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34339847

RESUMO

BACKGROUND: Medical treatment of inappropriate sinus tachycardia (IST) remains suboptimal. Radiofrequency sinus node (RF-SN) ablation has poor success and higher complication rates. OBJECTIVE: We aimed to compare clinical outcomes of the novel SN sparing hybrid ablation technique with those of RF-SN modification for IST management. METHODS: This is a multicenter prospective registry comparing the SN sparing hybrid ablation strategy with RF-SN modification. The hybrid procedure was performed using an RF bipolar clamp, isolating superior vena cava/inferior vena cava with the creation of a lateral line across the crista terminalis while sparing the SN region (identified by endocardial 3-dimensional mapping). RF-SN modification was performed by endocardial and/or epicardial mapping and ablation at the site of earliest atrial activation. RESULTS: Of the 100 patients (hybrid ablation group, n = 50; RF-SN group, n = 50), 82% were women, and the mean age was 22.8 years. Normal sinus rhythm and rate were restored in all patients in the hybrid group (vs 84% in the RF-SN group; P = .006). Hybrid ablation was associated with significantly better improvement in mean daily heart rate and peak 6-minute walk heart rate compared with RF-SN ablation. The RF-SN group had a significantly higher rate of redo procedures (100% vs 8%; P < .001), phrenic nerve injury (14% vs 0%; P = .012), lower acute pericarditis (48% vs 92%; P < .0001), permanent pacemaker implantation (50% vs 4%; P < .0001) than did the hybrid ablation group. CONCLUSION: The novel sinus node sparing hybrid ablation procedure appears to be more efficacious and safer in patients with symptomatic drug-resistant IST with long-term durability than RF-SN ablation.


Assuntos
Ablação por Cateter/métodos , Taquicardia Sinusal/cirurgia , Toracoscopia , Mapeamento Epicárdico , Feminino , Humanos , Masculino , Complicações Pós-Operatórias , Estudos Prospectivos , Sistema de Registros , Reoperação/estatística & dados numéricos , Taquicardia Sinusal/fisiopatologia , Adulto Jovem
15.
J Am Heart Assoc ; 10(19): e021370, 2021 10 05.
Artigo em Inglês | MEDLINE | ID: mdl-34569251

RESUMO

Background Endomyocardial biopsy (EMB) is part of 2010 Task Force Criteria (TFC) for arrhythmogenic right ventricular cardiomyopathy (ARVC). However, its usage has been curtailed because of its low presumed diagnostic yield, and it is now a poorly used tool. This study aims to analyze the contribution of EMB to the final diagnosis of ARVC. Methods and Results We included 104 consecutive patients evaluated for a suspicion of ARVC, who were referred for EMB. Patients with suspected left dominant pattern were excluded from the primary analysis. Subjects were initially stratified according to TFC without considering EMB. After EMB, patients were reclassified accordingly, and the reclassification rate was calculated. EMB yielded a diagnostic finding in 92 patients (85.5%). After including EMB evaluation, 20 (43%) more patients "at risk" received a definite diagnosis of ARVC. Overall, 59 patients received a definite diagnosis of ARVC, 34% only after EMB. EMB appeared to be the better-performing exam with respect to the final diagnosis (ß, 2.2; area uder the curve, 0.73; P<0.05). The reclassification improvement after EMB measured 28%. TFC score increased from 3.5±1.3 to 4.3±1.4 (P<0.001). Notably, active inflammation was present in 6 (10%) patients. Minor complications were reported in only 2% of the cohort. In patients with suspected left-dominant disease, conventional TFC performed poorly. Conclusions Electroanatomic voltage mapping-guided EMB was safe and yielded an optimal diagnostic yield. It allowed upgrading of the diagnosis of nearly one-third of the patients considered "at risk." Classical TFC without EMB performed poorly in patients with the left dominant form of ARVC.


Assuntos
Displasia Arritmogênica Ventricular Direita , Miocárdio , Displasia Arritmogênica Ventricular Direita/diagnóstico , Biópsia , Cateterismo Cardíaco , Humanos
16.
JACC Clin Electrophysiol ; 7(9): 1108-1117, 2021 09.
Artigo em Inglês | MEDLINE | ID: mdl-33933407

RESUMO

OBJECTIVES: This study aimed to assess the long-term outcomes of minimally fluoroscopic approach (MFA) compared with conventional fluoroscopic ablation (ConvA) in terms of recurrences of arrhythmia and long-term complications. BACKGROUND: Catheter ablation (CA) of supraventricular tachycardia (SVT) with an MFA, under the guidance of electroanatomic mapping (EAM) systems, results in a significant reduction in exposure to ionizing radiations without impairing acute procedural success and complication rate. However, data regarding long-term outcomes of MFA compared with ConvA are lacking. METHODS: This is a retrospective observational study. All patients undergoing MFA CA of SVT (atrioventricular nodal re-entrant tachycardia and atrioventricular re-entrant tachycardia) between 2010 and 2015 were enrolled and were compared with matched subjects (1 MFA: 2 ConvA) undergoing ConvA during the same period. The 2 co-primary outcomes were recurrence of arrhythmias and long-term complications. RESULTS: A total of 618 patients (mean age 38 ± 15 years, 60% female) were enrolled. MFA included 206 patients, whereas 412 were treated with ConvA. Acute success (99% vs. 97%; p = 0.10) and acute complications (2.4% vs. 5.3%; p = 0.14) were similar in the 2 groups. During a median follow-up of 4.4 years, 5.9% of patients experienced recurrence of arrhythmias. At multivariate analysis, ConvA (hazard ratio [HR]: 3.03) and procedural success (HR: 0.10) were independently associated with recurrence of arrhythmias. Late complications (i.e., advance atrioventricular block and need for pacemaker implantation) occurred more frequently in ConvA (3.4% vs. 0.5%; p = 0.03) compared with MFA. CONCLUSIONS: CA guided by EAM systems with MFA provided better long-term results and reduced risk of complications compared with ConvA.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Taquicardia Ventricular , Adulto , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento , Adulto Jovem
17.
Card Electrophysiol Clin ; 13(2): 303-311, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33990269

RESUMO

Intracardiac echocardiography (ICE) is a valuable tool and should be standard of care in any modern electrophysiology laboratory. Through real-time imaging of cardiac anatomy, ICE is used to guide electrophysiology procedures and monitor for complications. This article is a short overview of the application of real-time ICE imaging during atrial fibrillation ablation procedures.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Ecocardiografia/métodos , Cirurgia Assistida por Computador/métodos , Humanos
18.
J Interv Card Electrophysiol ; 61(1): 19-27, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32451798

RESUMO

PURPOSE: Idiopathic junctional ectopic tachycardia (JET) is typically refractory to antiarrhythmic agents. Catheter ablation for JET is feasible but is associated with high risk of unintended atrioventricular (AV) block. There is limited data on the appropriate procedural technique and clinical outcomes with catheter ablation for idiopathic JET in adults. METHODS: This is a multicenter, retrospective study of all adult patients (age ≥ 18 years) who underwent catheter ablation for idiopathic JET. Patient, procedural characteristics, and long-term outcomes were evaluated. RESULTS: Fifteen patients [radiofrequency ablation (RF) = 14 and cryoablation = 1) were treated with catheter ablation. The median age was 58 years with 67% males. All patients underwent mapping of the right atrium and the aortic cusps prior to energy delivery. The location of earliest activation in relation to the atrioventricular (AV) node was postero-superior in 73% (11/15), posterior in 13% (2/15), and superior in 13% (2/15) respectively. Acute success was 100%. Arrhythmia recurrence occurred in 53% (8/15) all of whom underwent a repeat ablation. High-grade AV block requiring permanent pacemaker occurred in 20% (3/15). At 12-month follow-up in the redo-ablation group, 37.5% (3/8) had recurrence of the arrhythmia two of which underwent a third ablation procedure. CONCLUSION: Catheter ablation of idiopathic JET in adults is associated with a high rate of recurrence requiring multiple procedures and high risk of AV block requiring a permanent pacemaker. Mapping and ablation of the non-coronary cusp can be considered as the arrhythmia was controlled in 3 patients with no inadvertent AV block.


Assuntos
Ablação por Cateter , Criocirurgia , Taquicardia por Reentrada no Nó Atrioventricular , Taquicardia Ectópica de Junção , Adulto , Nó Atrioventricular/cirurgia , Feminino , Humanos , Recém-Nascido , Masculino , Estudos Retrospectivos , Taquicardia por Reentrada no Nó Atrioventricular/diagnóstico por imagem , Taquicardia por Reentrada no Nó Atrioventricular/cirurgia , Taquicardia Ectópica de Junção/diagnóstico por imagem , Taquicardia Ectópica de Junção/cirurgia
19.
J Interv Card Electrophysiol ; 61(1): 45-53, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-32462549

RESUMO

BACKGROUND: Outflow tract (OT) premature ventricular contractions (PVCs) are commonly found in clinical practice; in most cases, PVCs are benign and observed in structurally normal hearts, not requiring any therapeutic intervention. In this study, we therefore sought to evaluate with cardiac magnetic resonance (CMR) patients with PVC and apparently normal heart at echocardiographic examination, in order to identify possible substrates linked with higher prevalence of arrhythmias or structural heart disease. METHODS: Thirty-three consecutive patients with frequent PVCs originating from the ventricular OT (right and left) were enrolled in the study and assessed by echocardiography and CMR. All patients had normal baseline electrocardiogram. RESULTS: CMR showed structural changes in 5 patients out of 33; in 3 cases, areas of fibrosis limited in one case to the middle basal segments of the interventricular septum and in two patients to the middle basal segments of the inferior-lateral wall were found. In 2 other cases, however, late gadolinium enhancement showed significant anomalies characterized in one patient by extensive areas of subepicardial fibrosis of the left ventricle, suitable with arrhythmogenic left dominant dysplasia; in another patient, a marked trabeculation of left ventricular medium apical segments suitable with non-compaction myocardium was present. CONCLUSIONS: CMR may identify cases of structural heart disease in subjects with OT PVCs and apparently normal electrocardiogram and echocardiogram examinations. A preliminary screening with CMR may be considered before any further invasive electrophysiology assessment and therapeutic planning.


Assuntos
Complexos Ventriculares Prematuros , Meios de Contraste , Gadolínio , Ventrículos do Coração/diagnóstico por imagem , Humanos , Espectroscopia de Ressonância Magnética , Complexos Ventriculares Prematuros/diagnóstico por imagem
20.
J Interv Card Electrophysiol ; 62(1): 187-198, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33009645

RESUMO

BACKGROUND: There is growing evidence in support of pulmonary vein isolation (PVI) with concomitant posterior wall isolation (PWI) for the treatment of patients with symptomatic persistent atrial fibrillation (persAF). However, there is limited data on the safety and efficacy of this approach using the cryoballoon. OBJECTIVE: The aim of this multicenter, investigational device exemption trial (G190171) is to prospectively evaluate the acute and long-term outcomes of PVI versus PVI+PWI using the cryoballoon in patients with symptomatic persAF. METHODS: The PIVoTAL is a prospective, randomized controlled study ( ClinicalTrials.gov : NCT04505163) in which patients with symptomatic persAF refractory/intolerant to ≥ 1 class I-IV antiarrhythmic drug, undergoing first-time catheter ablation, will be randomized to PVI (n = 183) versus PVI+PWI (n = 183) using the cryoballoon in a 1:1 fashion. The design will be double-blind until randomization immediately after PVI, beyond which the design will transform into a single-blind. PVI using cryoballoon will be standardized using a pre-specified dosing algorithm. Other empiric ablations aside from documented arrhythmias/arrhythmias spontaneously induced during the procedure will not be permitted. The primary efficacy endpoint is defined as AF recurrence at 12 months, after a single procedure and a 90-day blanking period. Arrhythmia outcomes will be assessed by routine electrocardiograms and 7-14 day ambulatory electrocardiographic monitoring at 3, 6, and 12 months post-ablation. CONCLUSION: The PIVoTAL is a prospective, randomized controlled trial designed to evaluate the outcomes of PVI alone versus PVI+PWI using the cryoballoon, in patients with symptomatic persAF. We hypothesize that PVI+PWI will prove to be superior to PVI alone for prevention of AF recurrence.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Humanos , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Método Simples-Cego , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA